Error code C-0011 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0011

 

Classification: Main body: Communication error

 

Cause: Drive communication reception error detection abnormality 8.

 Measures to take when alert occurs:                                                               The main body and the option stop immediately                

 Estimated abnormal parts:  

  • Printer control board (PRCB) 
  • PF drive board (PFUDB: PF-703/706)                                     
Correction: 

Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                   

Note: The message "Please turn on power again" is displayed on the touch panel.

Solution:                                                                                                               

  1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds.
  2. Check the connector connection and the wiring between PRCB and PFUDB, and repair it if any abnormality.
  3. Check the connector connection on PRCB and PFUDB, and repair it if any abnormality.
  4. Replace PFUDB.
  5. Replace PRCB. 