Error code C-0105 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0105
Classification: PF: Power abnormality
Cause:
Abnormality of the PF exit conveyance motor (M2) power in the PF drive board (PFUDB) of the first tandem PF-706.
An error detection signal (blowout of ICP) of M2 is detected when M2 is turned ON.
Measures to take when alert occurs: The main body and the option stop immediately.
Estimated abnormal parts:
- PF exit conveyance motor (M2: PF-706)
- PF drive board (PFUDB: PF-706)
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the touch panel.
Solution:
- Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality.
- Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality, and then replace the PFUDB (Wiring diagram: PF-706: 7-H).
- Replace M2 and PFUDB.
Related Solutions
Error code C-1555 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1555
Classification: PB: PB abnormality
Cause:
After warming-up is completed, the glue...
Error code C-1554 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1554
Classification: PB: PB abnormality
Cause:
The glue tank temperature sensor/Lw (TH...
Error code C-1553 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1553
Classification: PB: PB abnormality
Cause:
The glue tank temperature sensor/Md (TH...
Error code C-1552 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1552
Classification: PB: PB abnormality
Cause:
The glue tank temperature sensor/Up (T...
Error code C-1551 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1551
Classification: PB: PB abnormality
Cause:
The glue apply roller temperature senso...
Error code C-1559 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1559
Classification: PB: PB abnormality
Cause:
The glue apply roller temperature sensor ...
Error code C-1558 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1558
Classification: PB: PB abnormality
Cause:
After warming-up is completed, the glue t...
Error code C-1557 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1557
Classification: PB: PB abnormality
Cause:
After warming-up is completed, the glue t...
Error code C-1556 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1556
Classification: PB: PB abnormality
Cause:
When the glue supply control temperatu...
Error code C-1555 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1555
Classification: PB: PB abnormality
Cause:
After warming-up is completed, the glue...
Error code C-1554 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1554
Classification: PB: PB abnormality
Cause:
The glue tank temperature sensor/Lw (TH...
Error code C-1553 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1553
Classification: PB: PB abnormality
Cause:
The glue tank temperature sensor/Md (TH...
Error code C-1552 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1552
Classification: PB: PB abnormality
Cause:
The glue tank temperature sensor/Up (T...
Error code C-1551 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1551
Classification: PB: PB abnormality
Cause:
The glue apply roller temperature senso...
Error code C-1559 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1559
Classification: PB: PB abnormality
Cause:
The glue apply roller temperature sensor ...
Error code C-1558 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1558
Classification: PB: PB abnormality
Cause:
After warming-up is completed, the glue t...
Error code C-1557 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1557
Classification: PB: PB abnormality
Cause:
After warming-up is completed, the glue t...
Error code C-1556 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1556
Classification: PB: PB abnormality
Cause:
When the glue supply control temperatu...
Error code C-1555 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1555
Classification: PB: PB abnormality
Cause:
After warming-up is completed, the glue...