Shipping cutoff time is 3pm EST - Orders received after 3pm will be shipped out the following business day(Mon-Friday)Call Us: (800) 675 7821 - From 9:00 am EST to 5:00 pm EST(Mon-Friday)
Error code C-0111 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0111
Classification:Main body: Power abnormality
Cause:
Abnormality of the duplex section motor IC in the ADU drive board (ADUDB).
The error detection signals of the ADU reverse motor (M12), the reverse/exit motor (M13), the ADU accelerate motor (M14) and the ADU conveyance motor /1 (M15) are detected after the print is started.
Measures to take when alert occurs: The main body and the option stop immediately.
Estimated abnormal parts:
ADU reverse motor (M12)
Reverse/exit motor (M13)
ADU acceleration motor (M14)
ADU conveyance motor /1 (M15)
ADU drive board /1 (ADUDB 1)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the touch panel.
Solution:
Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality.
Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality and then replace M12, M13, M14, M15 (Wiring diagram: Main body (2/4): 19-P, 18-P, 7-P)