Error code C-0114 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0114
 Classification: Main body: Power abnormality
Cause: 
Abnormality 2 of the SD/CL_24V power for the printer control board (PRCB) tray.
When the error detection signal of the PRCB tray solenoid/clutch ICP blowout is detected but no 24V cut off is detected at the start.                                                                                                         
Measures to take when alert occurs:                                                               The main body and the option stop immediately.                                               
Estimated abnormal parts: 
  • Paper feed clutch /1 (CL4)
  • Separation clutch /1 (CL5)
  • Paper feed clutch /2 (CL6)
  • Separation clutch /2 (CL7)
  • Pick-up solenoid /1 (SD3)
  • Pick-up solenoid /2 (SD4)
  • Printer control board (PRCB)
Correction: 

Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.

 Note: "Please call service" is displayed on the touch panel.   

Solution:                                                                                                               

  1. Check the connector connection and the wiring related to DC24V between PRCB and clutch/solenoid, and repair it if any abnormality.
  2. Check the drive and the coupling of the clutch and the solenoid, repair it if any abnormality, and then replace PRCB (Wiring diagram: Main body (3/4): 16-A, 22-A, Main body: (3/4): 17-A)
  3. Replace PRCB
  4. Replace the clutch, the solenoid and PRCB at a time.