Error code C-0118 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0118
 Classification: PF: Power abnormality
Cause: 
Abnormality of the power for the PF drive board (PFUDB) SD/CL of the PF-703/706.
At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.                                                                                                 
Measures to take when alert occurs:                                                               The main body and the option stop immediately.                                               
Estimated abnormal parts: 
  • PF drive board (PFUDB: PF-703/706)
Correction: 

Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.

 Note: "Please call service" is displayed on panel.   

Solution:                                                                                                               

  1. Check the connector connection and the wiring on PFUDB, and repair it if any abnormality.
  2. Check the drive and the coupling of the solenoid and the clutch connected to PFUDB, repair/replace it if any abnormality, and then replace PFUDB.
  3. Replace PFUDB
  4. If the same error cord occurs even after replacing PFUDB, replace the connected solenoid, the clutch and PFUDB at a time.
Back to blog