Code: C-0118
Classification: PF: Power abnormality
Cause:
Abnormality of the power for the PF drive board (PFUDB) SD/CL of the PF-703/706.
At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.
Measures to take when alert occurs: The main body and the option stop immediately.
Estimated abnormal parts:
- PF drive board (PFUDB: PF-703/706)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on panel.
Solution:
- Check the connector connection and the wiring on PFUDB, and repair it if any abnormality.
- Check the drive and the coupling of the solenoid and the clutch connected to PFUDB, repair/replace it if any abnormality, and then replace PFUDB.
- Replace PFUDB
- If the same error cord occurs even after replacing PFUDB, replace the connected solenoid, the clutch and PFUDB at a time.