Code: C-0130
Classification: PF: Power abnormality
Cause:
1st PF-703 coupling conveyance motor/1 (M4) power abnormality.
An error detection signal (blowout of ICP) of M4 is detected when M4 is turned ON.
Measures to take when alert occurs: The main body and the option stop immediately.
Estimated abnormal parts:
- Coupling conveyance motor /1 (M4: PF-703)
- PF drive board (PFUDB: PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the touch panel.
Solution:
- Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality.
- Check the I/O drive and the coupling of the gear, repair/replace it if any abnormality, and then replace the PFUDB (Wiring diagram: PF-703: 20-L)
- Replace M4 and PFUDB at a time.