Code: C-0141
Classification: PI-PFU: Power abnormality
Cause:
PI-PFU (PF-703) PF exit conveyance motor (M3) power abnormality.
An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON.
Measures to take when alert occurs: The main body and the option stop immediately.
Estimated abnormal parts:
- PF exit conveyance motor (M3: PF-703)
- PF drive board (PFUDB: PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition
Note: The message "Please call service" is displayed on the panel.
Solution:
- Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality.
- Check the I/O drive and the coupling of the gear, and repair/replace it if any abnormality, and then replace the PFUDB (Wiring diagram: PF-703: 8-L)
- Replace M3 and PFUDB at a time.