Code: C-0144
Classification: PI-PFU: Power abnormality
Cause:
PI-PFU (PF-703) SD/CL power abnormality.
At the start, the error detection signal of the PFUDB solenoid/clutch IPC blowout id detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- PF drive board (PFUDB: PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition
Note: "Please call service" is displayed on the touch panel.
Solution:
- Check the connector connection and the wiring on PFUDB, and repair it if any abnormality.
- Check the drive and the coupling of the solenoid and the clutch connected to the PFUDB, repair/replace it if any abnormality, and then replace PFUDB
- Replace PFUDB
- If the same error cord occurs even after replacing PFUDB, replace the connected solenoid, the clutch and PFUDB at a time.