Code: C-0152
Classification: LU: Power source abnormality
Cause:
Abnormality of the paper lift motor (M100) power in the LU drive board (LUDB).
An error detection signal (blowout of ICP) of M100 is detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Paper lift motor (M100)
- LU drive board (LUDB)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition
Note: "Please call service" is displayed on the touch panel.
Solution:
- Check the connector connection and the wiring between LUDB and the motor, and repair it if any abnormality.
- Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality, and then replace M100 (Wiring diagram: LU: 5-C).
- Replace LUDB.
- Replace M100 and LUDB at a time.