Error code C-0164 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0164
 Classification: PF: Power abnormality
Cause: 
Abnormality of the power for SD or CL inside the PF drive board (PFUDB) of the 3rd tandem PF-703.
At the start, the error detection signal of the PFUDB solenoid ICP blowout or the PFUDB clutch ICP blowout is detected.                                                                                                                        
Measures to take when alert occurs:                                                              
The main body and the option stop immediately.                                               
Estimated abnormal parts:
  • PF drive board (PFUDB: PF-703)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition  
 
Note: "Please call service" is displayed on the touch panel.                                         

Solution:                                                                                                              

  1. Check the connector connection and the wiring on PFUDB, and repair it if any abnormality.
  2. Check the  drive and the coupling of the solenoid and the clutch connected to PFUDB, repair/ replace it if any abnormality, and then replace the PFUDB.
  3. Replace PFUDB.
  4. If the same error cord occurs even after replacing PFUDB, replace the connected solenoid, the clutch and PFUDB at a time.
Back to blog