Error code C-0222 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0222
Classification:PF: Tray3
Cause:
1st tandem PF-703/706 upper tray up abnormality.
PF-703: When the upper limit sensor / 1 (PS5) is OFF, PS5 does not turn ON within 20 seconds after the paper lift motor /1 (M7) turns on for lifting operation. Or, the paper suction sensor /Fr1 and /Rr1 (PS25 and PS26) turns ON while in tray lifting.
PF-706: When the upper limit sensor /1 (PS2) is OFF, PS2 does not turn ON within 20 seconds after the paper lift motor/1 (M42) turns ON for the lifting operation.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Upper limit sensor /1 (PS5: PF-703)
Upper limit sensor /1 (PS2: PF-706)
Paper lift motor /1 (M7: PF-703)
Paper lift motor /1 (M42: PF-706)
PF drive board (PFUDB: PF-703/706)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the touch panel.
Solution:
Check the paper loaded condition and the rear end restriction plate misaligned of the upper tray, and repair it if any abnormality.
Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality.
Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PF-703: 6-F, PF-706: 5-C).
Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: PF-703: 3-F, PF-706: 3-C)