Code: C-0252
 Classification: PI-PFU: PI Tray2
Cause: 
PI-PFU (PF-703) middle tray up abnormality.
When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20 seconds after the paper lift motor /2 (M8) turns On for lifting operation. Or, the paper suction sensor /Fr2 and /Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting.
                                                                                  
Measures to take when alert occurs:                                                              
The main body and the option stop immediately. 
        
Estimated abnormal parts:
  • Upper limit sensor /2 (PS9: PF-703)
  • Paper lift motor /2 (M8: PF-703)
  • PF drive board (PFUDB: PF-703)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                  
Note: The message "Please call service" is displayed on the panel.                                         
Solution:   
  1. Check the paper loaded condition and the rear end restriction plate misaligned of the middle tray, and repair it if any abnormality.
  2. Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality.
  3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PF-703: 12-F).
  4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: PF-703: 9-F)
  5. Replace PS9: PF-703
  6. Replace M8: PF-703
  7. Replace PFUDB
Back to blog