Error code C-0264 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0264
Classification:PF: Tray4
Cause:
1st tandem PF-703 shutter motor /2 (M11) operation time abnormality 2.
The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Shutter motor /2 (M11: PF-703)
PF drive board (PFUDB: PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: The message "Please call service" is displayed on the panel.
Solution:
Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality.
Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PF: PF-703: 17-L).