Error code C-0282 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0282
 Classification: PI-PFU: PI Tray1
Cause: 
PI-PFU (PF-703) shutter motor /1 (M10) operation time abnormality 2.
The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is detected.                                                                                      
Measures to take when alert occurs:                                                              
The main body and the option stop immediately. 
        
Estimated abnormal parts:
  • Shutter motor /1 (M10: PF-703)
  • PF drive board (PFUDB: PF-703)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                  
Note: The message "Please call service" is displayed on the panel.                                         
Solution:   
  1. Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality.
  2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PF: PF-703: 15-L).
  3. Replace M10 and PFUDB at a time.