Code: C-0292
Classification: PF: Tray9
Cause:
3rd tandem PF-703 shutter motor /1 (M10) operation time abnormality 2.
The EM error detection signal of M10 is detected twice in succession within a specified period of time after the M10 was activated. At this time, an error detection signal (blowout of the fan ICP) is also detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Shutter motor /1 (M10: PF-703)
- PF drive board (PFUDB: PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the touch panel.
Solution:
- Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality.
- Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PF: PF-703: 15-L).
- Replace M10 and PFUDB at a time.