Error code C-0296 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0296
 Classification: PF: Tray11
Cause: 
3rd tandem PF-703 shutter motor /3 (M12) operation time abnormality 2.
The EM error detection signal of M12 is detected twice in succession within a specified period of time after the M12 was activated. At this time, an error detection signal (blowout of the fan ICP) is also detected.
                                   
Measures to take when alert occurs:                                                            
The main body and the option stop immediately. 
        
Estimated abnormal parts:
  • Shutter motor /3 (M12: PF-703)
  • PF drive board (PFUDB: PF-703)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                 
Note:  "Please call service" is displayed on the touch panel.                                         
   Solution:
  1. Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality.
  2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PF-703: 19-L).
  3. Replace M12 and PFUDB at a time.