Code: C-0306
Classification: Main body: Fan abnormality
Cause: 
Paper cooling exit fan /Up (FM4) rotation abnormality.
The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, error detection signal (24V cut off) is not detected.                                  
Measures to take when alert occurs:                                                            
The main body and the option stop immediately. 
        
Estimated abnormal parts:
  • Paper exit cooling fan /Up (FM4)
  • Printer control board (PRCB)
  • AC drive board (ACDB)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                 
Note:  The message "Please call service" is displayed on the panel.                                         
   Solution:
  1. Check the connector connection and the wiring between PRCB and the fan, and repair it if any abnormality.
  2. Check the connector connection and the wiring between ACDB and the fan, and repair it if any abnormality.
  3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (2/4): 10-A)
  4. Replace FM4
  5. Replace PRCB.
  6. Replace ACDB.