Error code C-0310 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0310
Classification: Main body: Fan abnormality
Cause: 
Paper cooling exit fan /Lw2 (FM28) rotation abnormality + 24V power abnormality.
The FM28EM error detection signal is detected twice in succession within a specified period of time after FM28 was turned ON. At this time, an error detection signal (24V cut off) is detected. 
                                 
Measures to take when alert occurs:                                                            
The main body and the option stop immediately. 
        
Estimated abnormal parts:
  • DC power supply /2 (DCPS/2)
  • AC drive board (ACDB)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                 
Note:  The message "Please call service" is displayed on the panel.                                         
   Solution:
  1. Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality.
  2. Replace DCPS /2.
  3. Replace ACDB.
Back to blog