Error code C-0326 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0326
Classification:Main body: Fan abnormality
Cause:
Paper feed assist fan /Rr2 (FM24) rotation abnormality + 24V power abnormality.
The FM24 EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
DC power supply /2 (DCPS2)
Printer control board (PRCB)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: The message "Please call service" is displayed on the panel.
Solution:
Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality.