Error code C-0333 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0333
Classification: PF: Fan abnormality
Cause: 
3rd tandem PF-703 paper feed assist fan /Fr1 (FM1) rotation abnormality.
The EM error detection signal of the Fm1 is detected twice in succession within a specified period of time after the FM1 was activated. However, an error detection signal (blowout of ICP) is not detected.
                                 
Measures to take when alert occurs:                                                            
The main body and the option stop immediately. 
        
Estimated abnormal parts:
  • Paper feed assist fan /Fr1 (FM1: P-703)
  • PF drive board (PFUDB)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                 
Note:  "Please call service" is displayed on the touch panel.                                         
   Solution:
  1. Check the connector connection and the wiring between PFUDB and FM1, and repair it if any abnormality.
  2. Rotate the fan with I/O or by hand, and repair or replace it if there is any abnormality. (Wiring diagram: PF-703: 6-F).
  3. Replace FM1.
  4. Replace PFUDB.