Error code C-0338 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

by sherlyn planas on January 10, 2024
Code: C-0338
Classification: PF: Fan abnormality
Cause: 
3rd tandem PF-703 paper feed assist fan /Rr2 (FM6) power abnormality.
EM detection signal of the Fm6 is detected twice in succession within a specified period of time after the FM6 was activated. At this time, an error detection signal (blowout of ICP) is also detected.
                                 
Measures to take when alert occurs:                                                            
The main body and the option stop immediately. 
        
Estimated abnormal parts:
  • Paper feed assist fan /Rr2 (FM6: PF-703)
  • PF drive board (PFUDB)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                 
Note:  "Please call service" is displayed on the touch panel.                                         
   Solution:
  1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
  2. Rotate the fan with I/O or by hand, and repair or replace it if there is any abnormality. (Wiring diagram: PF-703: 11-F).
  3. Replace FM6 and PFUDB at a time.