Error code C-0341 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0341
Classification:PF:Fan abnormality
Cause:
1st tandem PF-703/706 paper feed assist fan /Fr1 (FM1) power abnormality.
The FM1EM error detection signal is detected twice in succession within a specified period of time after the FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Paper feed assist fan /Fr1 (FM1: PF-703/706)
PF drive board (PFUDB)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: The message "Please call service" is displayed on the panel.
Solution:
Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F, PF-706: 4-C).