Error code C-0345 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0345
 Classification: PF: Fan abnormality
Cause: 
1st tandem PF-703/706 paper feed assist fan /Rr1 (FM2) rotation abnormality.
The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
                                 
Measures to take when alert occurs:                                                            
The main body and the option stop immediately. 
        
Estimated abnormal parts:
  • Paper feed assist fan /Fr1 (FM2: PF-703/PF-706)
  • PF drive board (PFUDB)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                 
Note: The message  "Please call service" is displayed on the panel.                                         
   Solution:
  1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
  2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F).
  3. Replace FM2.
  4. Replace PFUDB.