Code: C-0353
Classification: PF: Fan abnormality
Cause:
1st tandem PF-703/706 paper feed assist fan /Fr3 (FM9:PF-703, FM5: PF-706) power abnormality.
The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Paper feed assist fan /Fr3 (FM9: PF-703)
- Paper feed assist fan /Fr3 (FM5: PF-706)
- PF drive board (PFUDB)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: The message "Please call service" is displayed on the panel.
Solution:
- Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
- Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 18-F, PF-706: 9-C).
- Replace FM9 and PFUDB at a time: PF-703 Replace FM5 and PFUDB at a time: PF-706