Shipping cutoff time is 3pm EST - Orders received after 3pm will be shipped out the following business day(Mon-Friday)Call Us: (800) 675 7821 - From 9:00 am EST to 5:00 pm EST(Mon-Friday)
Error code C-0356 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0356
Classification:PF:Fan abnormality
Cause:
1st tandem PF-703/706 paper feed assist fan /Rr3 (FM10:PF-703, FM6: PF-706) power abnormality.
The FM10 EM and FM6 EM error detection signals are detected twice in succession within a specified period of time after FM10 and FM6 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Paper feed assist fan /Rr3 (FM10: PF-703)
Paper feed assist fan /Rr3 (FM6: PF-706)
PF drive board (PFUDB)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: The message "Please call service" is displayed on the panel.
Solution:
Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F, PF-706: 9-C).
Replace FM10 and PFUDB at a time: PF-703 Replace FM6 and PFUDB at a time: PF-706