Call Us: (800) 675 7821

From 9:00 am to 5:00 pm (Mon-Friday)


Shipping cutoff time is 3pm EST

Orders received after 3pm will be shipped out

the following business day(Mon-Friday)

Error code C-0361 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

by sherlyn planas on January 17, 2024
Code: C-0361
Classification: PF: Fan abnormality
Cause: 
1st tandem PF-703 cooling fan rotation abnormality 2.
The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected.
                                 
Measures to take when alert occurs:                                                            
The main body and the option stop immediately. 
        
Estimated abnormal parts:
  • PF cooling fan /3 (FM21: PF-703)
  • PF drive board (PFUDB)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                 
Note: The message  "Please call service" is displayed on the panel.                                         
   Solution:
  1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
  2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 23-F).
  3. Replace FM21 and PFUDB.                                                                                                                                                                      
BACK TO TOP

Net Orders Checkout

Item Price Qty Total
Subtotal $0.00
Shipping
Total

Shipping Address

Shipping Methods