Shipping cutoff time is 3pm EST - Orders received after 3pm will be shipped out the following business day(Mon-Friday)Call Us: (800) 675 7821 - From 9:00 am EST to 5:00 pm EST(Mon-Friday)
Error code C-0363 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0363
Classification:PF: Fan abnormality
Cause:
3rd tandem PF-703 paper feed assist fan /Rr3 (FM9) power abnormality.
EM detection signal of the FM9 is detected twice in succession within a period of time after the FM9 was activated. However, an error detection signal (blowout of ICP) is not detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Paper feed assist fan /Fr3 (FM9: PF-703)
PF drive board (PFUDB)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the touch panel.
Solution:
Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
Rotate the fan with I/O or by hand, and repair or replaced it if there is any abnormality. (Wiring diagram: PF-703: 18-F).