Error code C-0367 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0367
Classification: PF: Fan abnormality
Cause:
3rd tandem PF-703 cooling fan rotation abnormality 1.
The EM error detection signals of the FM19 and the FM20 are detected twice in succession within a period of time after the PF cooling fan /1 and (FM19) and the PF cooling fan /2 (FM20) were activated. However, an error detection signal (blowout of ICP) is not detected.

Measures to take when alert occurs:
The main body and the option stop immediately.

Estimated abnormal parts:
  • PF cooling fan (FM7: PF-706)
  • PF cooling fan /1 (FM19: PF-703)
  • PF drive board (PFUDB)

Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.

Note: "Please call service" is displayed on the touch panel.

Solution:

  1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
  2. Rotate the fan with I/O or by hand, and repair or replace it if there is any abnormality. (Wiring diagram: PF-703: 22-F, 23-F).
  3. Replace FM19 and FM20.
  4. Replace PFUDB.
Back to blog