Error code C-0387 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0387
Classification: PI-PFU: Fan abnormality
Cause:
PI-PFU (PF-703) paper feed assist fan /Rr1 (FM2) power abnormality.
The EM error detection signal of Fm2 is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
                     

 Measures to take when alert occurs:

The main body and the option stop immediately.                                                 

Estimated abnormal parts:

  • Paper feed assist fan /Fr1 (FM2: PF-703)
  • Printer control board (PFUDB)

Correction:

Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.

Note: The message "Please call service" is displayed on the panel.                      
Solution:
  1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 
  2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: (PF-703: 6-F).
  3. Replace FM2 and PFUDB.                                                                                                                                          
Back to blog