Error code C-0390 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0390
Classification: PI-PFU: Fan abnormality
Cause:
PI-PFU (PF-703) paper feed assist fan /Fr2 (FM5) rotation abnormality.
The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
                     

 Measures to take when alert occurs:

The main body and the option stop immediately.                                                 

Estimated abnormal parts:

  • Paper feed assist fan /Fr2 (FM5: PF-703)
  • Paper feed assist fan /Fr2 (FM3: PF-706)
  • PF drive board (PFUDB)

Correction:

Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.

Note: The message "Please call service" is displayed on the panel.                      
Solution:
  1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 
  2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: (PF-703: 10-F, PF-706: 7-C).
  3. Replace FM5: PF-703                                                                                                                                                                       Replace FM3: PF-706
  4. Replace PFUDB.                                                                                                                                          