Error code C-0393 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0393
Classification: PI-PFU: Fan abnormality
Cause:
PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) power abnormality.
The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
                     

 Measures to take when alert occurs:

The main body and the option stop immediately.                                                 

Estimated abnormal parts:

  • Paper feed assist fan /Fr3 (FM9: PF-703)
  • Paper feed assist fan /Fr3 (FM5: PF-706)
  • PF drive board (PFUDB)

Correction:

Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.

Note: The message "Please call service" is displayed on the panel.                      
Solution:
  1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 
  2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: (PF-703: 18-F, PF-706: 9-C).
  3. Replace FM9 and PFUDB at a time: PF-703                                                                                                                                        Replace FM5 and PFUDB at a time: PF-706                                                                                                                                  