Code: C-0403
Classification: Main body: Power abnormality
Cause:
12V power abnormality in the printer control board (PRCB).
An error detection signal of the 12V in PFDB (blowout of ICP) is detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Printer control board (PRCB)
- DC power supply /2 (DCPS/2)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: The message "Please call service" is displayed on the panel.
Solution:
- Check the connector connection and the wiring on PRCB, and repair it if any abnormality.
- Replace PRCB.
- Replace DCPS /2