Code: C-0411
Classification: Main body: Power abnormality
Cause:
ADU drive board (ADUDB) power abnormality 1.
An error detection signal (blowout of ICP) of the transfer paper correction sensor (PS4), transfer exposure lamp (L4) or SD is detected. At this time, an error detection signal (24V cut off) is detected. 
                     

 Measures to take when alert occurs:

The main body and the option stop immediately.                                                 

Estimated abnormal parts:

  • ADU drive board /1 (ADUDB1)
  • DC power supply /1 (DCPS/1)

Correction:

Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.

Note: The message "Please call service" is displayed on the panel.                      
Solution:
  1. Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. 
  2. Replace ADUDB1.
  3. Replace DCPS /1                                                                                                                                                                                                                  