Error code C-0413 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0413
Classification: Main body: Power abnormality
Cause:
Interlock power abnormality of the ADU drive board (ADUDB).
An error signal of 24V interlock power is detected in the door detection closed status.
                     

 Measures to take when alert occurs:

The main body and the option stop immediately.                                                 

Estimated abnormal parts:

  • ADU drive board /1 (ADUDB1)
  • DC power supply /1 (DCPS/1)

Correction:

Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.

Note: The message "Please call service" is displayed on the panel.                      
Solution:
  1. Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. 
  2. Check the connector connection and the wiring between ADUDB1 and DCPS/1, and repair it if any abnormality.
  3. Replace ADUDB1.     
  4. Replace DCPS /1.                                                                                                                                                                                                          