Shipping cutoff time is 3pm EST - Orders received after 3pm will be shipped out the following business day(Mon-Friday)Call Us: (800) 675 7821 - From 9:00 am EST to 5:00 pm EST(Mon-Friday)
Error code C-0595 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0595
Classification:PF: PF power source abnormality
Cause:
3rd tandem PF-703 paper suction fan /6 (FM18) power abnormality.
After the FM18 becomes active, the FM18EM error detection signal is detected twice in succession with in a specified period of time. At this time, an error detection signal (blowout of ICP) is also detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Paper suction fan /6 (FM18: PF-703)
PF drive board (PFUDB: PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the touch panel.
Solution:
Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-L).