Error code C-0595 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0595
Classification: PF: PF power source abnormality
Cause:
3rd tandem PF-703 paper suction fan /6 (FM18) power abnormality.
After the FM18 becomes active, the FM18EM error detection signal is detected twice in succession with in a specified period of time. At this time, an error detection signal (blowout of ICP) is also detected. 
  
Measures to take when alert occurs:
The main body and the option stop immediately.                                                 

Estimated abnormal parts:

  • Paper suction fan /6 (FM18: PF-703)
  • PF drive board (PFUDB: PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note:  "Please call service" is displayed on the touch panel.
                      
Solution:
  1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 
  2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-L).
  3. Replace FM18 and PFUDB.          