Error code C-0673 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0673
Classification: PF: Heater high temperature abnormality
Cause:
PI-PFU (PF-703) dehumidification heater /3 (HTR3) high temperature hardware abnormality.
After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Lower tray fan heater (HT-505)
AC drive board /2 (ACDB/2: HT-505)
PF drive board (PFUDB- PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: The message "Please call service" is displayed on the panel.
Solution:
Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality.
Check the connector connection and the wiring between PFUDB and ACDB/2, and repair it if any abnormality.
Check the temperature and the installation of the fan heater, and repair it if any abnormality.
Replace the fan heater.
Replace ACDB/2.
Replace PFUDB.