Error code C-0685 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0685
Classification: PF: Heater high temperature abnormality
Cause:
3rd tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality.
After the power becomes active, the temperature sensor/5 (TEMS5) detects a heater abnormality signal.
  
Measures to take when alert occurs:
The main body and the option stop immediately.                                                 

Estimated abnormal parts:

  • Upper tray fan heater (HT-505)
  • AC drive board /2 (ACDB/2: HT-505)
  • PF drive board (PFUDB- PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note:  "Please call service" is displayed on the touch panel.
                      
Solution:
  1. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 
  2. Check the connector connection and the wiring between PFUDB and ACDB/2, and repair it if any abnormality.
  3. Check the temperature and the installation of the fan heater, and repair it if any abnormality.
  4. Replace the fan heater.
  5. Replace ACDB/2.
  6. Replace PFUDB.          