Code: C-1113
Classification: FS: FS-532 abnormality
Cause:
The stacker rear stopper home sensor (PS27) does not turn ON within a specified period of time after the home position search operation of the stacker movement monitor (M19) starts.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- FNS control board (FNSCB)
- Stacker movement motor (M19)
- Stacker rear stopper home sensor (PS27)
Correction:
Turn OFF/ON the sub power switch of the main body.
Note: The message "Please call service" is displayed on the panel.
Solution:
- Check the stapler rotation section, and clean/repair it if any abnormality.
- Check the connector connection and the wiring between FNSCB and the motor sensor, and repair it if any abnormality.
- Check the I/O drive of the motor of the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 5-F)
- Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 11-B)
- Replace PS27.
- Replace M19.
- Replace FNSCB.