Shipping cutoff time is 3pm EST - Orders received after 3pm will be shipped out the following business day(Mon-Friday)Call Us: (800) 675 7821 - From 9:00 am EST to 5:00 pm EST(Mon-Friday)
Error code C-1125 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1125
Classification: PI: PI abnormality
Cause:
The tray upper limit sensor /Up (PS205) or the tray lower limit sensor /Up (PS209) does not turn ON within the specified period of time after the tray up down motor /Up (M201) turns ON.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
FNS control board (FNSCB)
PI drive board (PIDB)
Tray up down motor /Up (M201)
Tray upper limit sensor /Up (PS205)
Tray lower limit sensor /Up (PS204)
Correction:
Turn OFF/ON the sub power switch of the main body.
Note: The message "Please call service" is displayed on the panel.
Solution:
Check the PI lower tray section, and clean/repair it if any abnormality.
Check the connector connection and the wiring between PIDB and motor/sensor, and repair it if any abnormality.
Check the connector connection and the wiring between FNSCB and PIDB, and repair it if any abnormality.
Check the I/O drive of the motor of the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PI: 4-B)
Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: PI: 4-B)