Error code C-1172 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1172
Classification: FS: FS-532 abnormality
Cause:

An error detection signal of FM1 is detected continuously for a specified period of time while the large size paper alignment fan (FM1) is ON.

Measures to take when alert occurs:

The main body and the option stop immediately.                                                 
Estimated abnormal parts:
  • FNS control board (FNSCB)
  • Large size paper alignment fan (FM1)
Correction:
Turn OFF/ON the sub power switch of the main body.
Note: The message "Please call service" is displayed on the panel.
                      
Solution:
  1. Check the connector connection and the wiring between FNSCB and  the fan, and repair it if any abnormality.
  2. Rotate the fan by I/O or hand, and repair it if any abnormality.(Wiring diagram: FS-532: 6-F)
  3. Replace FM1.
  4. Replace FNSCB. 