Error code C-1176 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1176
Classification: FS: SD-510 abnormality
Cause:
After the center paddle motor (M106) turns ON, the center paddle home sensor (PS108) does not turn ON within a specified period of time.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
FNS control board (FNSCB)
SD control board (SDCB)
Center paddle motor (M106)
Center paddle home sensor (PS108)
Correction:
Turn OFF/ON the sub power switch of the main body.
Note: The message "Please call service" is displayed on the panel.
Solution :
Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality.
Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality.
Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 3-G)
Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 4-B)
Replace PS108.
Replace M106.
Replace SDCB.
Replace FNSCB.
July 22 2024
sherlyn planas