Code: C-1179
Classification: FS: FS-532 abnormality
Cause:
RUKA communication error.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- FNS control board (FNSCB)
Correction:
Turn OFF/ON the sub power switch of the main body.
Note: The message "Please call service" is displayed on the panel.
Solution:
- Deactivate the sub power switch, and then become inactive the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds.
- Check the connector connection and the wiring between the main body and each option, and repair it when there is any abnormality.
- Check the connector connection of the control board and the drive board in each option, and repair it when there is any abnormality.
- Rewrite the firmware of the option.
- Replace the control board of the option corresponds to the malfunction code.