Code: C-1242
Classification: SD: SD-506 abnormality
Cause:
The folding main scan alignment home sensor/Fr1 (PS18) does not become active within a specified period of time after the folding main scan alignment motor/Fr (M7) starts the home position search operation. Alternatively, even after a specified period of time after M7 starts the operation, it does not stop.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Folding main scan alignment motor (M7)
- Folding main scan alignment home sensor (PS18)
- SD control board (SDCB)
- SD drive board (SDDB)
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note:
- When you isolate the faulty part, the limited use is available.
- The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press the help key, the message "Please turn on the power again" is displayed on the touch panel.
Solution:
- Check the folding main scan alignment section, and clean or repair it when there is any abnormality.
- Check the connector connection and the wiring between SDDB and the motor and the sensor, and repair it when there is any abnormality.
- Check the connector connection and the wiring between SDDB and SDCB, and repair it when there is any abnormality.
- Check the I/O drive of the motor and the coupling of the gear, and repair or replace it when there is any abnormality. (Wiring diagram: SD-506: 8-D).
- Check I/O and the operation of the sensor, and repair or replace it if there is any abnormality. (Wiring diagram: SD-506: 13-D).
- Replace PS18.
- Replace M7.
- Replace SDDB.
- Replace SDCB.