Code: C-1258
Classification: SD: SD-513 abnormality
Cause:
After the clamp motor (M37) starts the home position search operation, the clamp open close home sensor (PS31) does not become active within a specified period of time. Alternatively, during the clamp release operation, the PS31 does not become active within a specified period of time after M23 starts the operation. When M23 starts operation, the clamp motor encoder sensor (PS121) does not become active.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Clamp open close home sensor (PS31)
- Clamp motor encoder sensor (PS121)
- Clamp motor (M23)
- SD drive board (PCB2)
- SD control board (PCB1)
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note:
- Faulty part isolation allows you to use the machine temporarily.
- The message "Please call service" and "Press [Help] to disengage" are alternately displayed.
- When you press the help key, the message "Please turn on the power again" is displayed.
Solution:
- Check the clamp drive section, and if there is any abnormality, clean or repair it.
- Check the connector connection and the wiring harness between PCB2 and the motor, PCB1 and the sensor. Then, repair them when there is any abnormality.(Wiring diagram: SD-513 (2/2): 7-B) (Wiring diagram: SD-513 (2/2): 6-O, 7-O).
- Check the connector connection and the wiring harness between PCB2 and PCB1, and if there is any abnormality, repair them.
- Check the I/O drive of the motor and the coupling of the gear, and repair or replace it when there is any abnormality.
- Check I/O and the operation of the sensor, and if there is any abnormality, repair or replace it.
- Replace PS31 or PS121.
- Replace M23.
- Replace PCB2.
- Replace PCB1.