Error code C-1262 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1262
ClassificationSD: SD-513 abnormality
Cause:
After the initial operation is completed, an abnormality of the staple error (non staple) detection signal is detected. During the job or after the staple operation completes, an abnormality of the staple error (non staple) detection signal is detected.

 Measures to take when alert occurs:

         The main body and the option stop immediately.                                                 
Estimated abnormal parts:
  • Stapler ground switch/1 (SW6)
  • Stapler ground switch/2 (SW7)
  • SD drive board (PCB2)
  • SD control board (PCB1)
Correction:
         Press help key and activate and deactivate the sub power switch (SW2) of the main body.
Note: 
  • Faulty part isolation allows you to use the machine temporarily.
  • When you press HELP key, the message "Please call service" and "Press [Help] to disengage" are alternately displayed.   
  • When you press HELP key, the message "Please turn on the power again" is displayed.  
Solution:
  1. Check the stapler section, and if there is any abnormality, clean or repair it.
  2. Check the connector connection and the wiring between PCB2 and the switch, and if there is any abnormality, repair them.
  3. Check the connector connection and the wiring between PCB2 and PCB1, and if there is any abnormality, repair them.
  4. Replacement of SW6 or SW7.
  5. Replace PCB2.
  6. Replace PCB1.
Back to blog