Code: C-1263
Classification: SD: SD-513 abnormality
Cause:
After the trimmer blade motor (M31) starts the home position search operation, the trimmer blade home sensor (PS49) does not become active within a specified period of time. At the start, the activation of the PS49 and the trimmer blade upper limit sensor (PS50) are detected at the same time.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Trimmer blade home sensor (PS49)
- Trimmer blade upper limit sensor (PS50)
- Trimmer blade motor (M31)
- SD drive board (PCB2)
- SD control board (PCB1)
Press help key and activate and deactivate the sub power switch (SW2) of the main body.
Note:
- When you isolate the faulty part, the limited use is available.
- When you press HELP key, the message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
- When you press HELP key, the message "Please turn on the power again" is displayed on the touch panel.
Solution:
- Check the trimmer blade drive section, and if there is any abnormality, clean or repair it.
- Check the connector connection and the wiring harness between PCB2 and the motor, PCB1 and the sensor. Then, repair them when there is any abnormality. (Wiring diagram: SD-513 (2/2): 8-B) (Wiring diagram: SD-513 (2/2): 11-O).
- Check the connector connection and the wiring harness between PCB2 and PCB1, and if there is any abnormality, repair them.
- Check the I/O drive of the motor and the coupling of the gear, and repair or replace it when there is any abnormality.
- Check I/O and the operation of the sensor, and if there is any abnormality, repair or replace it.
- Replace PS49 or PS50.
- Replace M31
- Replace PCB2.
- Replace PCB1.