Code: C-1265
Classification: SD: SD-513 abnormality
Cause:
After the lifter plate movement motor (M22) starts the home position search operation, the lifter plate size home sensor (PS33) does not become active within a specified period of time.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Lifter plate size home sensor (PS33)
- Lifter plate movement motor (M22)
- SD drive board (PCB2)
- SD control board (PCB1)
Press help key and activate and deactivate the sub power switch (SW2) of the main body.
Note:
- Faulty part isolation allows you to use the machine temporarily.
- When you press HELP key, the message "Please call service" and "Press [Help] to disengage" are displayed alternately.
- When you press HELP key, the message "Please turn on the power again" displayed.
Solution:
- Check the lifter plate drive section, and if there is any abnormality, clean or repair it.
- Check the connector connection and the wiring harness between PCB2 and the motor, PCB1 and the sensor. Then, repair them when there is any abnormality. (Wiring diagram: SD-513 (2/2): 8-B) (Wiring diagram: SD-513 (2/2): 11-O).
- Check the connector connection and the wiring harness between PCB2 and PCB1, and if there is any abnormality, repair them.
- Check the I/O drive of the motor and the coupling of the gear, and repair or replace it when there is any abnormality.
- Check I/O and the operation of the sensor, and if there is any abnormality, repair or replace it.
- Replace PS33.
- Replace M22.
- Replace PCB2.
- Replace PCB1.