Measures to take when alert occurs:
- Reverse extra gate home sensor (PS66)
- Reverse extra gate motor (M46)
- SD drive board (PCB2)
- SD control board (PCB1)
- Faulty part isolation allows you to use the machine temporarily.
- When you press HELP key, the message "Please call service" and "Press [Help] to disengage" are alternately displayed.
- When you press HELP key, the message "Please turn on the power again" is displayed.
Solution:
- Check the reverse extra gate drive section, and if there is any abnormality, clean or repair it.
- Check the connector connection and the wiring harness between PCB2 and the motor, PCB1 and the sensor. Then, repair them when there is any abnormality. (Wiring diagram: SD-513 (1/2): 5-N) (Wiring diagram: SD-513 (1/2): 20-B).
- Check the connector connection and the wiring harness between PCB2 and PCB1, and if there is any abnormality, repair them.
- Check the I/O drive of the motor and the coupling of the gear, and repair or replace it when there is any abnormality.
- Check I/O and the operation of the sensor, and if there is any abnormality, repair or replace it.
- Replace PS66.
- Replace M46.
- Replace PCB2.
- Replace PCB1.