Code: C-1272
Classification: SD: SD-513 abnormality
Cause:
You conduct the output check of the I/O check mode (the M33 trimmer board attachment sequence) after the replacement of the trimmer board. Then, a specified period of time has pass. However, the trimmer board replacement sensor (PS53) does not become inactive.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Trimmer board replacement sensor (PS53)
- Trimmer board movement motor (M33)
- SD drive board (PCB2)
- SD control board (PCB1)
Press help key and activate and deactivate the sub power switch (SW2) of the main body.
Note:
- Faulty part isolation allows you to use the machine temporarily.
- When you press HELP key, the message "Please call service" and "Press [Help] to disengage" are alternately displayed.
- When you press HELP key, the message "Please turn on the power again" is displayed.
Solution:
- Check the trimmer board drive section, and if there is any abnormality, clean or repair it.
- Check the connector connection and the wiring harness between PCB2 and the motor, PCB1 and the sensor. Then, repair them when there is any abnormality. (Wiring diagram: SD-513 (2/2): 11-B) (Wiring diagram: SD-513 (2/2): 10-O).
- Check the connector connection and the wiring harness between PCB2 and PCB1, and if there is any abnormality, repair them.
- Check the I/O drive of the motor and the coupling of the gear, and repair or replace it when there is any abnormality.
- Check I/O and the operation of the sensor, and if there is any abnormality, repair or replace it.
- Replace PS53.
- Replace M33.
- Replace PCB2.
- Replace PCB1.