Error code C-1272 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1272
ClassificationSD: SD-513 abnormality
Cause:
You conduct the output check of the I/O check mode (the M33 trimmer board attachment sequence) after the replacement of the trimmer board. Then, a specified period of time has pass. However, the trimmer board replacement sensor (PS53) does not become inactive.

 Measures to take when alert occurs:

         The main body and the option stop immediately.                                                 
Estimated abnormal parts:
  • Trimmer board replacement sensor (PS53)
  • Trimmer board movement motor (M33)
  • SD drive board (PCB2)
  • SD control board (PCB1)
Correction:
         Press help key and activate and deactivate the sub power switch (SW2) of the main body.
Note: 
  • Faulty part isolation allows you to use the machine temporarily.
  • When you press HELP key, the message "Please call service" and "Press [Help] to disengage" are alternately displayed.
  • When you press HELP key, the message "Please turn on the power again" is displayed.

Solution:

  1. Check the trimmer board drive section, and if there is any abnormality, clean or repair it.
  2. Check the connector connection and the wiring harness between PCB2 and the motor, PCB1 and the sensor. Then, repair them when there is any abnormality. (Wiring diagram: SD-513 (2/2): 11-B) (Wiring diagram: SD-513 (2/2): 10-O). 
  3. Check the connector connection and the wiring harness between PCB2 and PCB1, and if there is any abnormality, repair them. 
  4. Check the I/O drive of the motor and the coupling of the gear, and repair or replace it when there is any abnormality.
  5. Check I/O and the operation of the sensor, and if there is any abnormality, repair or replace it.
  6. Replace PS53.
  7. Replace M33.
  8. Replace PCB2.
  9. Replace PCB1.