Measures to take when alert occurs:
- FD clamp pressure release home sensor/Rr (PS201)
- FD clamp open close sensor/Rr (PS202)
- FD clamp pressure release home sensor/Fr (PS205)
- FD clamp open close sensor/Fr (PS206)
- FD clamp motor/Rr (M202)
- FD clamp motor/Fr (M203)
- FD drive board (FDDB)
- SD control board (PCB1)
- Faulty part isolation allows you to use the machine temporarily.
- When you press HELP key, the message "Please call service" and "Press [Help] to disengage" are alternately displayed.
- When you press HELP key, the message "Please turn on power again" is displayed.
Solution:
- Check the clamp up down drive section, and if there is any abnormality, clean or repair it.
- Check the connector connection and the wiring harness between FDDB and the motor, PCB1 and the sensor. Then, repair them when there is any abnormality. (Wiring diagram: FD-504: 10-F, 11-F) (Wiring diagram: FD-504: 1-G 2-G, 3-G).
- Check the connector connection and the wiring harness between FDDB and PCB1, and if there is any abnormality, repair it.
- Check the I/O drive of the motor and the coupling of the gear, and repair or replace it if there is any abnormality.
- Check I/O and the operation of the sensor, and if there is any abnormality, repair or replace it.
- Replace PS201, PS202, PS205 or PS206.
- Replace M202 or M203.
- Replace FDDB.
- Replace PCB1.